Option

High-Precision Calibrator NC-200

High-Precision Calibrator NC-200

Features

Best of accuracy checker for your Differential Pressure-Type leaktester!

Specifications
Power 100 VAC 50/60Hz Optional depending on region:220 VAC,etc.
Differential Pressure Range 0〜999Pa(available for other range)
Minimum Display Unit 1Pa
Temperature Range 0〜50°C
Test Pressure Atmospheric pressure
Dimension/Weight H: 105mm W: 200mm D: 230mm 2kg

High-Precision Calibrator NC-201

High-Precision Calibrator NC-201

Features

Most suitable for checking sensibility of direct pressure type leak testers.

Specifications
Power 100 VAC 50/60Hz Optional depending on region:220 VAC,etc.
Pressure Range ±100kPa / 0〜1MPa
Minimum Display Unit 10Pa / 100Pa
Temperature Range 0〜50°C
Dimension/Weight H: 105mm W: 200mm D: 230mm 2kg

Digital Flowmeter FM-100

Pushing Test Machine NP-600

Features

Most suitable to be incorporated in your flow measurement equipment!

Specifications
Power 100 VAC 50/60Hz Optional depending on region:220 VAC,etc.
Display Range 0〜±9999
Accuracy ±(0.03%of rdg+2digit)
Comparative Output Displayed value > Upper limit value (HI)
Lower limit value ≦ Displayed value ≦ Upper limit value (GO)
Lower limit value ≦ Displayed value (LO)
Detection Accuracy ±1% Repeatability ±0.5
Flow Measurement 10、50、100、300、500mL/min
1.2L/min
Temperature Range 0〜50°C
Test Pressure 0〜500kPa
Dimension/Weight H: 85mm W: 195mm D: 230mm 2kg

Digital Leak Check Meter DLC-100

Digital Leak Check Meter DLC-100

Features

Enabling you to generate a desired small amount of leakage.

Specifications
Power 100 VAC 50/60Hz Optional depending on region:220 VAC,etc.
Display Range 0〜±9999
Flow Measurement 10,50,100,300 mL/min
Temperature Range 0〜50°C
Test Pressure 0〜500kPa
Dimension/Weight H: 105mm W: 200mm D: 230mm 2kg

Leak Gauge NLG-100

Leak Gauge NLG-100

Features

Enabling you to generate a specified leak rate.

Specifications
Minimum Flow Measurement 0.2 mL/min
Piping Diameter M5
Temperature Range 0〜40°C
Test Pressure 0〜700kPa
Dimension H: 48mm W: 18mm D: 18mm

Leak Check Meter NT-100

Leak Check Meter NT-100

Features

Enabling you to generate a desired small amount of leakage.

Specifications
Accuracy FS±2%
Flow Measurement 0.5 mL/min
Temperature Range 0〜50°C
Test Pressure 0〜700kPa
Dimension H: 160mm W: 70mm D: 100mm

Calibrator Volume Change Type NT-110

Calibrator Volume Change Type NT-110

Features

Most suitable for checking sensibility of differential pressure type leak testers.

Specifications
Display Range 0〜500Pa
Test Pressure Atmospheric pressure
Dimension H: 80mm W: 150mm D: 100mm

Calibrator Volume Change Type NT-120

Calibrator Volume Change Type NT-120

Features

Volume and differential pressure can be checked quantitatively with this calibrator.

Specifications
Piping Diameter PT 1/8
Internal volume 0〜1 mL
Temperature Range 0〜50°C
Test Pressure 0〜700kPa
Dimension H: 93mm W: 21mm D: 21mm

Bluetooth NLT-BLU

Bluetooth NLT-BLU

Features

Leak tester measurement data can be sent to the personal computer by wireless and stored in it.

Specifications
Power 5 VDC
Data 1,048,576 data with Excel 2007 or later
Communication Range 10m Type, 100m Type(depending on the conditions of use)
Frequency 10m:2402〜2480MHz
100m:2400〜2483.5MHz
Connection RS232C
Applicatoin Soft Hyper Terminal or Tera Term., which will be prepared by the user.
Accessory USB Dongle, Instruction manual

SD MEMO

SD MEMO

Features

Leak tester measurement data can be sent to the personal computer by wireless and stored in it.

Specifications
Power 5 VDC
Data Capable of storing 60,000 data(depending on the SD memory capacity, up to 2 G).
1,048,576 data with Excel 2007 or later
Display Indication of the state such as error or writing by LEDs
Connection RS232C
Accessory Connecting cable(Leak Tester ⇔ SD MEMO)
DC Power, Instruchion manual
Dimension H: 23mm W: 103mm D: 62mm

Simple Remote Switch

Simple Remote Switch

Features

1. To start and stop the leak tester from a distance is possible.
2. To change the channel of the leak tester from a distance is possible.
3. I/O cables can be connected to the leak tester.

Specifications
Power 100 VAC 50/60Hz Optional depending on region:220 VAC,etc.
Dimension H: 85mm W: 195mm

High Functional Remote Switch

High Functional Remote Switch

Features

1. To start and stop the leak tester from a distance is possible.
2. To change the channel of the leak tester from a distance is possible.
3. I/O cables can be connected to the leak tester.
4. Equipped with lamps indicating the judgment of the leak tester, which enables you to know the result at a glance.
5. Equipped with a warning buzzer to sound on judgement of NG.
6. Enabling you to know the number of accepted products.

Specifications
Power 100 VAC 50/60Hz Optional depending on region:220 VAC,etc.
Dimension H: 100mm W: 250mm D: 210mm

Master Cylinder NBS-100

Master Cylinder NBS-100

Features

1. Capable of being used with various types of objects.
2. A fine adjustment of the volume is possible.
3. Since a scale is provided, the setting is easy.
 NOTE: The shape and size vary with the volume.

Internal Volume Range
0〜50mL
0〜100mL
0〜250mL
0〜500mL
0〜1000mL
0〜2000mL
0〜3000mL
Contact us others.

Dimensions Including the Mount

Dimensions Including the Mount

Spring-Back Unit

Spring-Back Unit

Features

After test, loosening the release valve will lower the jack automatically.

Example of Print

Example of Print

Display Unit with Printer

Display Unit with Printer

Features

Pressing the print switch will print out the weight at that time.
NOTE: The display unit with a printer is 65 mm higher than standard unit.

Laser Beam Pointer

Laser Beam Pointer

Features

Since the laser beam pointer, when installed, indicates the center of the fracture portion, anyone can make a measurement without dispersion.

Display Unit with USB Port

Display Unit with USB Port

Features

Equipped with a 3.5-inch color touch panel. The date, time and load value data can be stored in CSV format.
NOTE: The display unit with a USB port is 65 mm higher than the standard unit.